MIL-DTL-32628/01-X Reusable EMI Shield Termination Band on MIL-DTL-38999 Electrical Connector Accessory Braid Termination/Tensile Qualification Test
Reusable constant force spring force bands (CFSB), employed on shielded wire harness constructions to secure the shield onto the connector accessory/backshell banding platform in order to protect the wires in the bundle from electromagnetic interference (EMI), were evaluated for tensile strength performance as described in SAE AS85049™ and AS85049/128™.
Reusable constant force spring force bands (CFSB) M32628/ 01-10 thru 13 (ISOTDS1 thru 4) shield termination bands were evaluated for tensile strength performance as described in SAE AS85049™ and AS85049/128™. The M32628/01 shield termination bands are employed on shielded wire harness constructions to secure the shield on to the connector accessory/back-shell banding platform in order to protect the wires in the bundle from electromagnetic interference (EMI).

Four sizes of constant force spring bands were tested applied to eight shell sizes of connector accessories/backshells. The CFSBs were installed on A-A-59569 shield braid of suitable width, on shell size A- H of M85049/88™ backshells, mated to interface connector fixtures. The M85049/ 88™ backshells mate to the Mil-Dtl-38999 Series 3 connectors. The braid retention/tensile test requirements are per AS85049/ 128F™, para 2a. To pass the test, the M32628/01-10 thru -13 constant force spring band test articles may not shift, loosen, break or slip after exposure to the prescribed linear force.
For the band termination test, a 6-inch braid was clamped by each specimen to the accessory. The braid shell was tin coated copper in accordance with a-a-59569 with a 90% coverage. Two specimens each were clamped to an m85049/82-10*03, m85049/82-18*03, and m85049/82-28*03 accessory respectively.
For the braid retention test, the braid was pulled at a rate of 1 inch per minute to a force of 100 pounds minimum for braid .50 inch and under and 150 pounds minimum for braid over .50 inch. The braid could not pull out, and band slippage could not exceed .025 inch when measured from a fixed point on the adapter. Braid breakage due to tensile load was not viewed as a failure.
The AS85049/128F™ para 2a test was performed to assess the tensile strength performance characteristics of the M32628/10-10 thru -13 (ISOTDS1 thru 4) reusable constant force shield bands when installed on the legacy Mil-Dtl-38999 Series III compatible M85049/ 88™ EMI accessory. All shell sizes were tested, versus only the three called out in the AS85049/128F™ para 2.

All backshells tested were M85049/ 88™, size -9 thru -23 (A-H). They were aluminum base metal, with W=Cadmium plating per AS85049™ with the suitable cable entry sizes.
Specimens were tested using an electromechanical 100 KN MTS load frame. A smaller 10 KN load cell was utilized to minimize error in the test data. Specimens were fixtured using a mechanical wedge grip and fittings that were manufactured to interface with the different connector assemblies.
The tensile test setup was programmed to apply a tensile load by increasing the displacement between fixed ends of the assembly using a rate of 1 inch per minute until the desired load was reached. For accessory shell sizes 9 thru 19 connectors, a minimum force of 100 pounds was the required load while using .50 inch or less width braid. For the shell sizes 21 and 23, the minimum force applied was 150 pounds as the braid was wider than .50 inches (one inch). Once the maximum force requirement was reached, the applied force dwell/hold was one minute on average.
This work was done by Oliviu (Ollie) Muja and Matthew Stanley for the Naval Air Warfare Center Aircraft Division. For more information, download the Technical Support Package (free white paper) below. NAWC-0004
This Brief includes a Technical Support Package (TSP).

MIL-DTL-32628/01-X Reusable EMI Shield Termination Band on MIL-DTL-38999 Electrical Connector Accessory Braid Termination/Tensile Qualification Test
(reference NAWC-0004) is currently available for download from the TSP library.
Don't have an account? Sign up here.
Top Stories
INSIDERAerospace
Air Force Completes First Magnetic Navigation Flight on C-17 - Mobility...
INSIDERMaterials
University of Rochester Lab Creates New 'Reddmatter' Superconductivity Material...
INSIDERResearch Lab
Air Force Performs First Test of Microwave Counter Drone Weapon THOR - Mobility...
INSIDERElectronics & Computers
MIT Report Finds US Lead in Advanced Computing is Almost Gone - Mobility...
INSIDERDefense
Navy Selects Lockheed Martin and Raytheon to Develop Hypersonic Missile -...
INSIDERSoftware
Boeing to Develop Two New E-7 Variants for US Air Force - Mobility Engineering...
Webcasts
Automotive
How Metal Additive Manufacturing Is Driving the Future of Tooling
Software
Microelectronics Design Security: Better with Formal Methods
Defense
Solving Complex Thermal Challenges of Today’s Space Market
Manufacturing & Prototyping
Traction-Motor Innovations for Passenger and Commercial Electric...
Medical
5 Ways to Test Wearable Devices
Software
Mastering the Challenges of the Software Defined Vehicle: Digital...