NO-Generating Coats for Subcutaneous Glucose Sensors
These implantable sensors can be used for monitoring diabetes patients.
In a research program now in progress, polymeric materials that catalyze the generation of nitric oxide (NO) at low concentrations are being developed and tested for utility as coatings on surgically implantable amperometric glucose sensors. Heretofore, efforts to develop subcutaneous sensors for real-time clinical monitoring of glucose concentrations in diabetic patients have been stymied by inflammatory/foreign-body responses to implantation of sensors. The present research program follows from an observation, made in a related prior research program, that local generation of NO at low concentrations enhances the biocompatibility of implanted sensors by reducing inflammatory responses.

The focus of this research program is, more specifically, to develop new biomedical hydrogel and polyurethane coating materials containing immobilized copper(II) ions or other chemical species (e.g., organoselenium) that act as catalysts for in situ conversion of endogenous nitrosothiol compounds (e.g., nitrosoglutathione and nitrosocysteine) to NO, thereby enabling sustained local generation of NO at the surfaces of the implanted sensors. One of the accomplishments thus far has been the synthesis and characterization of a new material that includes a Cu(II)- cyclen compound covalently attached to a cross-linked poly (2-hydroxy- ethyl methacrylate). This material has been found to generate NO from endogenous nitrosothiols in solution at physiological pH. In preliminary in vivo studies using a lipophilic Cu(II)- cyclen compound blended into a biomedical-grade polyurethane coating material on sham subcutaneous devices implanted in rats, an apparent reduction in inflammatory response was demonstrated (see figure). However, proof that NO is the agent causing the observed improvement has yet to be obtained.
Needle-type subcutaneous glucose sensors that are to be coated with various NO-generating materials are undergoing development. At the time of reporting the information for this article, it was planned to use these sensors in experiments to determine (1) whether the NO-generating chemistry is compatible with the glucose-sensing chemistry and (2) whether the sensing function is compromised by coating with the NO-generating materials.
This work was done by Mark. E. Meyerhoff of the University of Michigan for the Army Research Laboratory.
This Brief includes a Technical Support Package (TSP).

NO-Generating Coats for Subcutaneous Glucose Sensors
(reference ARL-0037) is currently available for download from the TSP library.
Don't have an account?
Top Stories
INSIDERSoftware
The Future of Aerospace: Embracing Digital Transformation and Emerging...
INSIDERMaterials
Clean Sky Demonstrator Fuselage Shows Potential of Thermoplastics in Aircraft...
INSIDERTest & Measurement
Blue Origin Rocket Reaches Intended Orbit on First Launch
NewsAutomotive
AVSC Develops Best Practices for Traceable AV Safety Inspection Protocols
INSIDERRF & Microwave Electronics
First F-15Es Equipped With EPAWSS Ready for Flight
NewsPower
Webcasts
Software
Navigating Security in Automotive SoCs: How to Build Resilient...
Propulsion
Is Hydrogen Propulsion Production-Ready?
AR/AI
AI-Powered Quality Control for Sustainable Automotive Production
Aerospace
Improving Thermal Management for Aerospace and Defense Electronics
Connectivity
The Road Ahead for Next-Gen E/E Architectures: Trends and...
Software
Department of Defense Contracts Denied: New Cybersecurity Rules...